SKU
HI84502-02

Titratable Acidity Mini Titrator for Wine HI84502

In stock

This product is dangerous. Please request a quotation for this product.

The HI84502-02 is a simple, fast, and accurate automatic mini titrator designed for the determination of pH and titratable acidity in wine, juice, and must. This mini titrator uses a optimized preprogrammed method and a specialized wine pH electrode to give a highly accurate determination of pH and titratable acidity.
  • Complete kit for titratable acidity in wine.
  • Dynamic dosing makes testing both faster and more accurate.
  • Great for small & medium wineries and advanced hobbyists

Details

Acids occur naturally as grapes grow and during the eventual fermentation process. Wines have lower levels of acid when there is a hot growing season or when the grapes come from warmer regions. In the proper proportion, acids are a desirable trait, giving the wine a distinct character. The three predominant acids in wine are tartaric, malic and citric. Tartaric acid is the principal acid in grapes and is a component that promotes a crisp flavor and graceful aging in wine. A moderate amount of a wine’s acid comes from malic acid, which contributes to fruitiness. A small amount of titratable acidity comes from citric acid. Wine also contains trace amounts of other acids; the least desirable acid in wine is acetic acid, which, when present in more than a nominal amount, gives wine a sour or vinegary aspect. Total acidity, also called titratable acidity, is the sum of the fixed and volatile acids. In the United States, the total acidity is usually expressed in terms of tartaric acid, even though other acids are also measured. Titratable acidity directly affects the color and flavor of wine and, depending on the style of the wine, is sought in a perfect balance with the sweet and bitter sensations of other components. Too much acidity makes wine tart and sharp; too little makes wines flat and uninteresting. Proper acidity in wine is what makes it refreshing and an ideal accompaniment to food. The proper acid level of a wine varies, with sweeter wines generally requiring somewhat higher levels to retain the proper balance.

Application-Specific pH Electrode

The HI84502-02 is supplied with the HI1048B glass body pH electrode featuring CPStechnology to prevent the clogging of the reference junction. Conventional electrodes may clog quickly in biological samples that have a high solids content such as wine must. By design, the HI1048B pH electrode utilizes a polytetrafluoroethylene (PTFE) sleeve junction which controls a steady, predictable flow of electrolyte solution, keeping the junction open. The hydrophobic properties of PTFE repel wetness and coatings.

Piston Driven Dosing Pump

The heart of the HI84502-02 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the wine titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.

Automatic Stirrer

The built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.

HI84532-Help

Easy-to-Use Interface The HI84502-02 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and wine titration.

HI84500-Procedure-Warnings

Procedure Warnings Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.

HI84532-Titration-Curve

Graphic Mode This mini titrator displays in-depth data during titration, including a real-time graph of the wine titration curve.

HI84532-Log-Recall

Log-on-Demand The HI84502-02 allows for data logging of up to 400 samples: 200 titration results and 200 pH/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.

HI84530-pH-Electrode-Condition

pH/mV Meter In addition to being an automatic titrator, the HI84502U-01 also can be used as a pH/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.

hi84529-cal

CAL Check Accuracy is always ensured with Hanna’s unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84502U-01 is used as a pH meter, but also an accurate titration since the endpoint of a total acidity titration is determined by a set pH value.

 

Specifications

sku

HI84502-02

Range

Low Range: 0.1 to 5.0 g/L of tartaric acid
High Range: 4.0 to 25.0 g/L of tartaric acid

Resolution

0.1 g/L (ppt)

Accuracy (@25ºC/77ºF)

3% of reading or ±0.1 g/L, whichever is greater

Sample Volume

Low Range: 10 mL
High Range: 2 mL

Methods

acid base titration

Principle

endpoint titration: 7.00 pH or 8.20 pH

Pump Speed

10 mL/min

Stirring Speed

600 rpm

pH Range

-2.0 to 16.0 pH; -2.00 to 16.00 pH

pH Resolution

0.1 pH / 0.01 pH

pH Accuracy (@25ºC/77ºF)

±0.01 pH

pH Calibration

one, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01)

Temperature Compensation

manual or automatic

mV Range

-2000.0 to 2000.0 mV

mV Resolution

0.1 mV

mV Accuracy (@25ºC/77ºF)

±1.0 mV

Temperature Range

-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K

Temperature Resolution

0.1°C; 0.1°F; 0.1K

Temperature Accuracy (@25ºC/77ºF)

±0.4°C; ±0.8°F; ±0.4 K

Logging Data

up to 400 ( 200 titrations, 200 pH/mV readings)

Electrode

HI1048B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)

Temperature Probe

HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)

Environment

0 to 50°C (32 to 122°F); RH max 95% non-condensing

Power Supply

12 VDC adapter (included)

Dimensions

235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)

Weight

1.9 kg (67.0 oz.)

Ordering Information

HI84502 is supplied with HI1048B pH electrode, HI7662-T temperature probe, HI7082 electrode fill solution (30 mL), HI84502-50 (230 mL) titration solution, HI84502-55 pump calibration standard (120 mL), 100 mL beakers (2), dosing pump valve, 2000 ?L automatic pipette with plastic tips (2), 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, cleaning solution sachets for wine deposits, cleaning solution sachets for wine stains (2), 12 VDC adapter and instruction manual.

Warranty

2 years