Designed to maintain constant pH and disinfectant levels in swimming pools, hot tubs, and spas, the BL122, and BL123 pH and ORP controller offers the added benefit of allowing remote connection and access to devices via the Hanna Cloud web app.
Request a quotation
This product cannot be purchased online. Fill in the form to get a quotation, thank you.
Equipped with two peristaltic dosing pumps with replaceable chemical resistant tubing that are proportionally controlled with adjustable flow rates.
Adjust the proportional band based on the sensitivity of your process to chemical addition, finetuning the amount of time that the pumps are dosing.
The dosing pump flow rate is adjustable from 0.5 to 3.5L/h, allowing for better control in maintaining a desired set point.
Transfer data to a PC using a flash drive and the USB port or connect via the Ethernet Port to the Hanna Cloud.
Connect a flow switch so that when there is no flow or no power applied to the recirculation pump, the hold circuit will disable the dosing pumps to prevent any dosing when there is no movement of water in the system.
The BL123 pH and ORP controller offers three 4-20 mA outputs that can be disabled or connected to an external recording device. Each of the three measured parameters (pH, ORP, and temperature) can be assigned to an analog output.
Set low and high alarm levels for all parameters. When an alarm is activated, all dosing will stop to prevent overdosing.
Readings are automatically logged every 10 seconds. Logged data includes pH, ORP, and temperature values, last calibration data, setup configuration, and any event data.
GLP stores pH/ORP calibration information including date and time for pH/ORP sensors.
Password protection restricts access to calibration, setup, and review of logged data for increased security.
The LCD can display all 3 parameters at one time, a 3-second cycle of single parameters, or a real-time graph.
Hanna Cloud is a web-based application that connects you to measurement devices such as the BL122 and BL123. Measurements and data storage are accessible from your PC, tablet or phone. Measurements, trends, history, device settings, alarms, and messages are transmitted to your “Dashboard” as your instrument measures and controls your process.
Measurement & Graphing
Measurement, alarm, hold and pump status are easily viewable. Use a graph to view trends over the last 12 hours or change the time period. Log history can be transferred as a PDF or .CSV.
Good Laboratory Practices (GLP)
Good Laboratory Practice (GLP) refers to a quality control function used to ensure uniformity of probe calibrations and measurements. GLP data is readily available for increased traceability.
Notifications
Select which notifications you would like to receive. Multiple secondary users may also be added to your device account to monitor measurements and receive email or pop-up messages from your process device.
Specification Name | Detail |
Product name | pH and ORP controller BL122/BL123 |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy (@25°C/77°F) | ±0.05 pH |
pH Dosing | proportional with adjustable set point and proportional band; delay to start at power-on and overdosing protection |
ORP Range | ±2000 mV |
ORP Resolution | 1 mV |
ORP Accuracy (@25°C/77°F) | ±5 mV |
ORP Dosing | proportional with adjustable set point and proportional band; delay to start at power-on and overdosing protection; pH dosing interlocked |
Temperature Range | -5.0 to 105.0°C (23.0 to 221.0°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy (@25°C/77°F) | ±1°C (±1.8°F) |
Temperature Compensation | automatic, -5.0 to 105.0°C (23.0 to 221.0°F) for pH |
Calibration | pH buffer calibration: automatic, two-point (4.01, 7.01, 10.01 pH) pH process calibration: one-point, manual input |
Pump Control | automatic and manual modes; adjustable flow rate from 0.5 to 3.5 L/h |
Log Feature | automatic logging of pH, ORP, and temperature measurements, GLP and events including alarms, errors and power failure; capacity for 60 days with 10 second sampling interval; all data .csv files are transferred by USB flash drive |
Alarms | high and low with enable/disable option for all parameters; alarm is triggered when 5 consecutive readings are over/under threshold |
Alarm System | intuitive alert system based on LEDs; alarm filtering options; alarm relay control based on user setup |
Password Protection | setup, calibration and log recall options features are password protected |
Connectivity | USB |
GLP | pH/ORP calibration information including date and time for pH/ORP sensors |
Alarm Relay Output | SPDT 5A/230 VAC; activated by pH/ORP/temperature selectable alarm conditions |
Analog Outputs | 4 to 20 mA, sourcing, configurable; output impedance ≤ 500 Ohm; accuracy < 0.5 % FS; galvanically isolated up to 50 V relative to earth ground |
Auxiliary Inputs | low level in acid/base tank (contact open); low level in chlorine tank (contact open); hold input (contact open) |
Digital Probe Input | galvanic isolated digital input HI1036-1802 pH/ORP/temperature/matching pin combined probe with DIN waterproof connector |
Power Supply | 100 — 240 VAC |
Power Consumption | 10 VA |
Environment | 0 to 50°C (32-122°F); max 95% RH non-condensing |
Dimensions | 245 x 188 x 55 mm (73 mm with pumps); 9.6 x 7.4 x 2.2” (2.9” with pumps) |
Weight | 1700 g (60 oz.) |
Industry | |
---|---|
Parameter |
We have over 3.000 products in our catalogue. Register now and download the catalogue or contact us and see if we can help you.
With Great Products, Come Great Results
All prices are VAT excluded and without shipping costs, unless otherwise stated.
Hanna Service d.o.o. — Sermin 75H, Bertoki — 6000 Koper (Slovenia) — VAT ID SI92346669
©2019 All rights reserved
Login to your account or create one right now to access to our exclusive content.