HANNA Instruments Logo
SKU HI5222-01 Categories ,

Laboratory Research Grade Two Channel Benchtop pH/mV/ISE Meter - HI5222

All prices are VAT excluded and without shipping costs, unless otherwise stated.

The HI5222 is an advanced research grade dual channel benchtop pH/ISE/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5222 is rich in features including 5 point calibration, selectable resolution, data logging, alarm limits, comprehensive GLP, and much more. It retains simplicity with both dedicated key for routine operation and virtual keys that guide the user through setup options.

The HI5222 ensures confidence in measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.

Buy now with confidence

 971,25

5 in stock

Request a quotation

This product cannot be purchased online. Fill in the form to get a quotation, thank you.

The HI5222 is an advanced research grade benchtop pH/mV/ISE dual channel meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5222 features two galvanically isolated BNC connections for use with the expansive line of pH, ISE and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over
a wide range of temperature from 0 to 100°C. All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe that is included.

As a pH meter the HI5222 can be calibrated up to five points with eight pre-programmed buffers or five custom buffers. The HI5222 features Hanna’s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process. Indicators displayed during calibration include “Electrode Dirty/Broken” and “Buffer Contaminated.” The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. As an ISE meter the HI5222 can be calibrated up to five points with a choice of five fixed standards or five user defined in any

concentration unit. The calibration data including date, time, standards used and
slope can be viewed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option. Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points per channel can be recorded in 100 lots, 50,000 records max/lot and exported to a computer for data review and storage.

Customizable User Interface

The user interface of the HI5222 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate. Programmable alarm limits can be set to inside or outside allowable limits. Color Graphic LCD The HI5222 features a color graphic LCD with
on-screen help, graphic, and custom color configurations. The display allows for realtime graphing and the use of virtual keys provide for an intuitive user interface.

Capacitive Touch

The HI5222 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue.

Two Galvanically Isolated pH/ORP/ISE Channels

The HI5222 has two input channels that can be used for pH, ORP and ISE electrodes. Each input channel has connectors for BNC probes, reference probes and a temperature sensor. Each channel is galvanically isolated which means that two measurement probes can be in the same solution at the same time and the voltages produced will not interfere with each other.

Choice of Calibration

Automatic buffer recognition, semi automatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers.

GLP Data

HI5222 includes a GLP Feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data include date, time, buffers used for calibration, and electrode offset and slope characteristics.

CAL Check™

CAL Check alerts users to potential problems during the calibration of the pH electrode. Indicators include “Electrode Dirty/Broken,” “Buffer Contaminated,” electrode response time and the overall probe condition as a percentage that is based on the offset and slope characteristics. ISE Measurement with Choice of

Concentration Units

The HI5222 allows for calibration and readings in choice of concentration units. The choices of concentration units include ppt, g/L, mg/mL, ppm, mg/L, μg/mL, ppb, μg/L, mg/mL, M, mol/L, mmol/L, %w/v and a userdefined unit.

ISE Measurement with Incremental Methods

The known addition, known subtraction, analyte addition, and analyte subtraction

incremental methods are pre-programmed into the HI5222. Simply follow the on screen guided procedure and the meter will perform the calculation automatically allowing for a higher level of accuracy to be obtained as compared to a direct ISE measurement.

Data Logging

Three selectable logging modes are available on the HI5222: automatic, manual, and AutoHold logging. Automatic and manual logs up to 100 lots with 50,000 records max/lot with up to 100,000 total data points per channel. Automatic logging features the option to save data according to sampling period and interval.

Data Transfer

Data can be transferred to a PC with USB cable and HI92000 software (both sold
separately).

Contextual Help

Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

Calibration CAL CHECK
Logging
Good Laboratory Practice GLP

CAL Check Feature

Comprehensive GLP Data

Comprehensive GLP Data

Laboratory pH meter

Dual Channels

The two measurement channels of the HI5222 are galvanically isolated to eliminate noise and instability. In ISE mode, this instrument provides a choice of several incremental methods. Communication is via opto-isolated USB.

Specifications

pH

Range

-2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH

Resolution

0.1, 0.01, 0.001 pH

Accuracy

±0.1 pH; ±0.01 pH; ±0.002 pH ±1 LSD

Calibration

automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,
12.45), and five custom buffers

Temperature Compensation

automatic or manual from -20.0 to 120.0°C/-4.0 to 248.0°/253.15 to 393.15K

mV

Range

±2000 mV

Resolution

±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD

Accuracy

±0.2 mV ±1 LSD

Relative mV Offset Range

±2000 mV

ISE

Range

1 x 10-6 to 9.99 x 1010 concentration

Resolution

1; 0.1; 0.01; 0.001 concentration

Accuracy

±0.5% (monovalent ions); ±1% (divalent ions)

Calibration

automatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit,
and five user defined standards

Temperature

Range

-20.0 to 120°C; -4.0 to 248.0°F; 253.15 to 393.15K

Resolution

0.1°C; 0.1°F; 0.1K

Accuracy

±0.2°C; ±0.4°F; ±0.2K

Additional Specifications

pH Electrode

HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)

Temperature Probe

HI7662-W stainless steel temperature probe with 1 m (3.3’) cable (included)

Input Channels 

2 pH/ORP/ISE

GLP

calibration points, calibration time stamp, probe offset, slope, date, time and buffers/standards used

Logging

record : Up to 100 lots, 50,000 records max/lot / maximum 100,000 data points/channel; interval: 14 selectable between 1 second and 180 minutes; type: automatic, manual, AutoHOLD;

Display

color graphic LCD 240×340 pixels

PC Connection

USB

Power Supply

12 VDC adapter (included)

Environment 

0 to 50°C (32 to 122°F; 273 to 323K) RH max 95% non-condensing

Dimensions

160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)

Weight

1.2 kg (2.64 lbs.)

Ordering information

HI5222-02 (230V) is supplied with HI1131B pH electrode, HI7662-W temperature probe, pH 4.01 buffer solution sachet (2), pH 7.01 buffer solution sachet (2), HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), HI76404W electrode holder, 12 VDC adapter, capillary dropper pipette, quality certificate, quick start guide and instruction manual.

Additional Informations

Additional information

Industry

Parameter

,

Quotation request

Note: fields marked with * are mandatory.

Can't you find what you need?

We have over 3.000 products in our catalogue. Register now and download the catalogue or contact us and see if we can help you.

Login