HANNA Instruments Logo
SKU HI981413 Category

GroLine Nutrient Dosing System - HI981413

Developed to be an inexpensive solution for the horticulturist, the HI981413 Nutient Dosing System is engineered for maintaining the EC and TDS of nutrient solutions and irrigation water. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.

  • Available in multiple configurations.
  • Programmable alarm system and multicolored LCD display
  • Perfect for small hydroponics systems

Buy now with confidence

 295,00 495,00

Clear

Request a quotation

This product cannot be purchased online. Fill in the form to get a quotation, thank you.

Nutrient Dosing System

Peristaltic Dosing Pump

The powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.

Automatic Proportional Pump Control

The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point.

Adjustable Flow Rate

The dosing pump flow rate is adjustable from 0.5 to 3.5L/h, allowing for better control in maintaining a desired set point.

Acid Tank Level/Flow Switch Input

A connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.

Multicolored LCD Display

A multi-colored LCD provides a quick way to see the status of the pool controller. The display will show green when operation normally and red while in an alarm state.

Quick Connect Probe Input

The Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.

Nutrient Dosing System
Nutrient Dosing System

GroLine EC/Temperature Probe

The HI981413 uses the HI30033 amplified probe that incorporates both EC (TDS) and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.

  • PVDF body
  • 1/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell
Specification NameDetail
SKUHI981413
Temperature Range-5.0 to 105°C (23.0 to 221.0°F)
Temperature Resolution0.1°C (0.1°F)
Temperature Accuracy (@25°C/77°F)±0.5°C (±0.9°F)
EC Range0.00 to 10.00 mS/cm
EC Resolution0.01 mS/cm
EC Accuracy (@25°C/77°F)±2% F.S.
TDS Range0 to 4500 ppm (TDS conversion factor 0.45)
0 to 9900 ppm (TDS conversion factor 0.99)
TDS Resolution1 ppm
TDS Accuracy (@25°C/77°F)±2% F.S.
TDS Conversion FactorTDS conversion factor selectable from 0.45 to 0.99
Temperature Compensationautomatic
Temperature Coefficientβ can be set from 0%/°C to 2.4%/°C; default is 1.9%/°C
CalibrationEC: user calibration: automatic, one-point with standard solution (1.413 or 5.000 mS/cm)
Process calibration: single point, adjustable (±0.50 mS/cm around measured value)
TDS: through EC calibration
Pump Controlselectable flow rate (0.5 to 3.5 L / hour; 0.13 to 0.92 G/hour)
manual control for pump priming
Alarmshigh and low with enable / disable option
triggered after 5 sec. if controller records a set of consecutive readings over / under threshold values level with enable / disable option
overtime protection (1 to 180 min. or off)
intuitive alarm system using red, light green, and green color-coded backlight
External Event Inputinput for level controller or flow switch to disable dosing pump in the event of no chemical when using a level controller or no flow when using a flow switch – galvanically isolated
Alarm Relay OutputSPDT 2.5A / 230 VAC
Power Supply100—240 VAC, 50/60 Hz
Power Consumption15 VA
Casingwall mounted, built-in pump, IP65 rated
Environment0-50°C (32-122°F), max. 95% RH non-condensing
Dimensions90 x 142 x 80 mm (3.5 x 5.6 x 1.8”)
Weight910 g (32 oz.)
Ordering InformationHI981413-00 is supplied with HI30033 EC/TDS/temperature probe, conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.
HI981413-10 (with in-line mounting kit) is supplied with HI981413 controller, HI30033 EC/TDS/temperature probe, controller aspiration filter, controller injector, 1/2” thread, saddle for Ø 50 mm pipe (2), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (5 m), valves (2), conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.
HI981413-20 (with flow-cell mounting kit) is supplied with HI981413 controller, HI30033 pH/temperature probe, flow cell for HI981413/BL101, mounting panel assembly for HI981413/BL101, controller aspiration filter, controller injector, 1/2” thread, saddle for Ø 50 mm pipe (3), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (15 m), tubing adapter 1/2” – 6 mm with racord (2), valves (2), conductivity calibration solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.
Recommended ProbeHI30033 EC/TDS/Temperature probe with quick connect DIN connector – galvanically isolated

Additional Informations

Additional information

Industry

Quotation request

Note: fields marked with * are mandatory.

Can't you find what you need?

We have over 3.000 products in our catalogue. Register now and download the catalogue or contact us and see if we can help you.

Login

Login to your account or create one right now to access to our exclusive content.