The HI96701 portable photometer is for the measurement of free chlorine in a wide variety of water samples. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
CAL Check™ – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.
GLP – Records the date of the last user calibration performed.
Built in timer – Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.
Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.
Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.
Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.
Battery status indicator
The instrument has a battery level indicator to display reaming life as follows:
Units of measure – Appropriate unit of measure is displayed along with reading.
Free chlorine is one of the oldest and most common forms of disinfection, chlorine improves water quality by destroying disease-producing microorganisms, and by reacting with other organic and inorganic substances. Chlorine levels must be actively monitored to ensure sufficient chlorine is present for disinfection, as well as to control adverse effects, such as taste, odor and potential reactions with organic matter to form harmful disinfection byproducts.
The HI96701 uses an adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G to measure free chlorine concentrations of less than 5.00 mg/L (ppm). When the DPD reagent is added to samples containing free chlorine, the sample will turn a pink hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complimentary color, and the emitted radiation is dependent upon concentration. For free chlorine determination, a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.
*Reagents ordered separately
The HI96701-11 CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check function.
Provided storage containers
Absorbance
Light Source
tungsten lamp
Light Detector
silicon photocell with narrow band interference filter @ 420 nm
Free Chlorine
Range
0.00 to 5.00 mg/L (ppm)
Resolution
0.01 mg/L (ppm) from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy
±0.03 mg/L ±3% of reading
Method
adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G
Battery Type
9V battery
Auto-off
after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions
193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Weight
360g (12.7oz.)
Ordering information
HI96701 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
Industry |
---|
We have over 3.000 products in our catalogue. Register now and download the catalogue or contact us and see if we can help you.
With Great Products, Come Great Results
All prices are VAT excluded and without shipping costs, unless otherwise stated.
Hanna Service d.o.o. — Sermin 75H, Bertoki — 6000 Koper (Slovenia) — VAT ID SI92346669
©2021 All rights reserved
Login to your account or create one right now to access to our exclusive content.