The HI87314 is a durable, portable EC and resistivity meter designed for use in applications such as manufacturing and quality control. It is supplied with a four-ring conductivity probe to allow for four ranges of EC measurement and one range of resistivity measurement The temperature compensation coefficient (β) is adjustable from 0 to 2.5%/°C for conductivity and from 2 to 7%/°C for resistivity. All readings are automatically adjusted for temperature, assuring users of consistent and accurate measurements.
  • EC and Resistivity Portable Meter
  • Four-ring probe
  • Adjustable temperature coefficient (β)

Buy now with confidence

 456,75

5 in stock

Request a quotation

This product cannot be purchased online. Fill in the form to get a quotation, thank you.

Details

The portable HI87314 EC and resistivity meter is suitable for use in a wide range of applications. It offers four conductivity measurement ranges from 0.0 µS/cm to 199.9 mS/cm with ±1% FS accuracy as well as a resistivity measurement range from 0 to 19.90 MΩ•cm with ±2% FS accuracy. The HI76302W four-ring conductivity probe that is supplied with the meter allows for a wide range of measurements with a single sensor. The four-ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI87314 offers Automatic Temperature Compensation (ATC) from 0 to 50°C (32 to 122°F) and an adjustable temperature coefficient (β).

Features at-a-glance

Four-Ring EC Probe  The HI76302W four-ring probe that comes with the HI87314 offers a versatile and accurate solution for conductivity readings. Four-ring technology allows for a larger range of measurement within a single probe, whereas two probe technology is somewhat limited in the range in which it can measure. The probe comes with a protective PVC sleeve that assures durability when taking measurements outdoors, and a built-in temperature sensor to allow for automatic temperature compensation.

Resistivity Probe  The HI3316D resistivity probe is also included with the HI87314 portable meter. Specially designed to measure resistivity, the easy to maintain probe features a built-in temperature sensor for accurately compensated resistivity readings.

Four EC Measurement Ranges  HI87314 offers four conductivity measurement ranges. Each range has a dedicated button on the face of the meter, allowing users to easily switch between ranges when necessary. The meter is programmed to let the user know when their current reading is out of range, and a new range should then be selected.

Automatic Temperature Compensation  Since temperature has such a dramatic effect on conductivity and resistivity readings, having a meter that offers temperature compensated readings is invaluable. Both probes that are supplied with the HI87314 feature built-in temperature sensors that automatically account for the effects of temperature on a sample’s reading in the range of 0 to 50°C (32 to 122°F).

Adjustable Temperature Coefficient  As the temperature of a solution increases or decreases, the conductance becomes higher or lower, respectively. The temperature compensation coefficient, also known as β, is the factor that adjusts for the temperature of a solution to ensure an accurate reading is achieved. The HI87314 allows for an adjustable β to be set from 0 to 2.5%/°C for conductivity and from 2 to 7%/°C for resistivity; this factor corrects readings by the set percentage for each degree Celsius change in the sample.

One-point Calibration –  The HI87314 can be calibrated at one point in a standard conductivity solution. The calibration knob located in the battery compartment of the meter is easily adjusted to the correct calibration standard.

Specifications

Conductivity

Range

0.0 to 199.9 μS/cm; 0 to 1999 μS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm

Resolution

0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm

Accuracy

±1% FS (excluding probe error)

Calibration

manual, one point

Resistivity 

Range

0 to 19.90 MΩ•cm

Resolution

0.10 MΩ•cm

Accuracy

±2% FS

Calibration

manual, one point

Temperature Compensation

automatic from 0 to 50°C with β selectable from 0 to 2.5%/°C for EC and from 2 to 7%/°C for resistivity

Additional Specifications

Probe

HI76302W conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable; HI3316D resistivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable

Battery Type

9V / approximately 100 hours of continuous use

Environment

0 to 50°C (32 to 122°F); RH max 100%

Dimensions

145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)

Weight

230 g (8.1 oz)

Ordering information

HI87314 is supplied with HI76302W conductivity probe, HI3316D resistivity probe, HI70030 calibration solution sachet, calibration screwdriver, battery, instructions and hard carrying case.

Additional Informations

Additional information

Industry

Meter type

Parameter

Quotation request

Note: fields marked with * are mandatory.

Can't you find what you need?

We have over 3.000 products in our catalogue. Register now and download the catalogue or contact us and see if we can help you.

Login

Login to your account or create one right now to access to our exclusive content.