Mo — Fr / 9.00 — 17.00| +386 5 902 99 03|WhatsApp
The Hanna PCA300 series chlorine analyzers continuously monitor, control, and adjust chlorine content and pH of a sample stream. From drinking and wastewater treatment to pool and spa sanitation, monitoring chlorine levels has an important bearing on public health as well as ROI and efficiency for heating system and industrial applications.
Request a quotation
This product cannot be purchased online. Fill in the form to get a quotation, thank you.
Four chlorine levels can be adjusted by the operator: a proportional dosing setpoint, two alarm setpoints, and a minimum level for dosing. Three pH levels can be adjusted by the operator: a dosing setpoint and two alarm setpoints. Two alarm levels can be set for temperature and ORP. All alarms can be enabled or disabled.
Users have the ability to enable or disable the low and high level of alarms for all parameters. The system also offers overdosing protection that generates an alarm if something within the system is not working properly. The system will stop processes until the error is corrected by the user.
The analyzers can store up to 3500 readings (at least 7 days at 3 minutes sampling interval) that can be available for consulting or downloading. Logged records contain the time stamp, full information about the parameter values and the alarm status at the time.
Five analog outputs of 0-10 mV, 0-100 mV, 0-1 V, 4-20 mA or 0-20 mA are available to drive external devices, including connection to SCADA systems. The analog output is fully programmable and can be proportional with chlorine concentration, pH, ORP or temperature value. The limits of the analog output are selectable for each parameter.
The PCA has a control time cycle that can be set by the user according to the dimensions of the controlled system. The measurement process, dosing commands, and alarms can be performed according to this time cycle. The range of cycle timing is from 3 to 90 minutes.
These controllers are offered in an easy to access, wall mounted casing that offers outstanding chemical, mechanical, and temperature resistance.
FREE AND TOTAL CHLORINE | PCA310, PCA320, PCA330 & PCA340 |
Range | 0.00 to 5.00 mg/L (ppm) |
Resolution | 0.01 mg/L (ppm) |
Accuracy | ±8% or ±0.05 mg/L whichever is greater |
pH | PCA320, PCA330 & PCA340 only |
Range | 0.00 to 14.00pH |
Resolution | 0.01pH |
Accuracy | ±0.05pH |
ORP | PCA330 only |
Range | 0 to 2000 mV |
Resolution | 1 mV |
Accuracy | ±1 mV |
TEMPERATURE | PCA320, PCA330 & PCA340 only |
Range | 5°C to 75.0°C |
Resolution | 0.1°C |
Accuracy | ±0.5°C |
ANALOGUE OUTPUT – PCA340 only | (2) 4-20mA, 0-20mA for recorder or dosing |
Chlorine Calibration | one-point process calibration |
Chlorine Sampling Rate | Adjustable from 3 to 90 minutes |
Chlorine Dosage | proportional |
Chlorine Delta | Selectable from 0.1 to 5 mg/L (ppm) |
pH Calibration | Automatic one or two points; one point process calibration |
pH Sampling Rate | Adjustable from 3 to 120 seconds |
pH Dosing | ON/OFF or proportional, relay or 4-20mA output |
pH Delta | Selectable from 0.1 to 2pH (hysteresis adjustable from 0.05 to 2pH |
Recorder output – PCA310, PCA320 & PCA330 | 4-20mA, 0-20mA |
PC Connectivity | RS485 port, galvanically isolated |
Baud Rate | 1200, 2400, 4800, 9600 bps |
Data logging | up to 3500 data points |
Alarm relay | SPDT contact with 5A, 230V resistive load |
Dosing relay | SPDT contact with 5A, 230V resistive load |
System error | SPDT contact with 5A, 230V resistive load |
Inlet pressure | 0.07 to 4 bar with no external pressure regulator (for pressure exceeding four bar an external pressure regulator is required) |
Sample flow | 100 to 300 mL/min |
Sample temperature | 5 to 40°C |
Sample inlet/outlet connection | 12mm male NPT fitting |
Drain connection | 10mm barb |
Power supply | 230 VAC ±10% |
Enclosure | NEMA-4X Standard, moulded fiberglass polyester with transparent Lexan window |
Dimensions/weight | 318 x 267 x 159mm/5kg without reagents |
PCA310 | Free and total chlorine analyser/controller (230V) |
PCA320 | Free and total chlorine analyser/control, pH control, temperature (230V) |
PCA330 | Free and total chlorine analyser/control, pH control, ORP monitoring, temperature (230V) |
PCA340 | Free and total chlorine analyser/control, pH control, temperature with dual analogue outputs (230V) |
PARTS | |
HI-70473 | PCA tubing kit, pressure regulator to drain (2). Each kit includes: transparent Tygon tubes 86L x 3.2ID mm (Length x Internal Diameter) and 105 x 9.5 mm |
HI-70474 | PCA peristaltic pump tubing kit (6). Each kit includes: non- transparent C-flex tubes 55L x 0.8ID mm |
HI-70475 | PCA peristaltic pump tubing kit (2). Each kit includes: non- transparent C-flex tubes 55L x 0.8ID mm |
HI-70476 | PCA reagent bottle tubing kit (6). Each kit includes: non- transparent C-flex tubes 155L x 0.8ID mm |
HI-70478 | PCA tubing kit, bottle to pump (6 ). Each kit includes: non- transparent C-flex tube 150L x 0.8ID mm |
HI-70479 | PCA tubing kit, pump to Y strainer (6 pcs). Each kit includes: non-transparent C-flex tube 150L x 0.8ID mm |
HI-70482 | PCA filters. The kit includes 0.5 µm and 50 µm filters |
HI-70496 | Replacement filter, 0.5 µm |
HI-70497 | Replacement filter, 50 µm |
HI-70484 | PCA complete tubing kit. The kit includes: non-transparent C-flex tubes 150L x 0.8ID (4 pcs), non-transparent C-flex tubes 55L x 0.8ID (2 pcs), non-transparent C-flex tubes 50L x 0.8ID and Y strainer |
HI-70485 | PCA stirrer motor |
HI-70486 | PCA Stirring bar |
HI-704871 | Measuring cell |
HI-70488 | Electrovalve 24VAC/60Hz |
HI-70489 | Electrovalve 24VAC/50Hz |
HI-70492 | Electrode holder (PCA330) |
HI-70493 | Closing cap for electrode holder |
ELECTRODES | |
HI-1005 | Amplified pH electrode with matching pin and Pt100 (PCA320/330 only) |
HI-2008 | Amplified ORP electrode with Matching Pin (PCA 330 only) |
REAGENT SETS | |
HI-70481 | Total Chlorine Reagent set for PCA buffer citrate, 500ml |
HI-70430 | Free chlorine reagents set for PCA (the most stable), recommended for long term measurements, 500 mL (2) + 6 g powder |
HI-70480 | Free chlorine reagents set for PCA, recommended for short term measurements, 500 mL (2) + 5 sachets (DPD) |
HI-70490 | Free chlorine reagents set for PCA, 500 mL (2) + 5 sachets (DPD) |
HI-70452 | DPD reagent, 5 sachets |
SOLUTIONS | |
HI-70460 | Total chlorine indicator solution for PCA, 500ml* (*After addition of 5 powder sachets (HI-70452-0) |
HI-70461 | Total chlorine buffer solution for PCA, 500ml |
HI-70450 | Free chlorine indicator solution for PCA, 500ml* (*After addition of 5 powder sachets (HI-70452-0) |
HI-70451 | Free chlorine buffer solution for PCA, 500ml |
HI-7004L | pH 4.01 buffer solution, 500ml |
HI-7006L | pH 6.86 buffer solution, 500ml |
HI-7007L | pH 7.01 buffer solution, 500ml |
HI-7009L | pH 9.18 buffer solution, 500ml |
HI-7010L | pH 10.01 buffer solution, 500ml |
HI-7020L | 200-275mV buffer solution, 500ml |
HI-7091L | Pretreatment reducing solution, 500ml |
HI-7092L | Pretreatment oxidizing solution, 500ml |
HI-70300L | Storage solution, 500ml |
HI-7082 | 3.5M KCL electrolyte, 30ml |
HI-7061L | Electrode cleaning solution, 500ml |
SOFTWARE | |
HI-92500 | Windows® compatible software |
Industry | |
---|---|
Parameter | |
PCA-Family | PCA(310) Chlorine, PCA(320) Chlorine, pH and Temperature, PCA(330) Chlorine, pH, ORP and Temperature, PCA(340) Chlorine, pH, ORP and Temperature /w dual channel |
We have over 3.000 products in our catalogue. Register now and download the catalogue or contact us and see if we can help you.
With Great Products, Come Great Results
All prices are VAT excluded and without shipping costs, unless otherwise stated.
Hanna Service d.o.o. — Sermin 75H, Bertoki — 6000 Koper (Slovenia) — VAT ID SI92346669
©2019 All rights reserved
Login to your account or create one right now to access to our exclusive content.