Plating pH meter - HI99131
- ±0.02 pH accuracy
- Comes with all the necessary solutions and batteries- everything you need to get started measuring right away.
- Specialized for the direct pH measurement of plating baths.
Probe Condition
An on-screen indicator provides visual confirmation that your probe is working at its best.
Low Battery Indicator
The included batteries provide 1200 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.
Automatic Shut-off
The auto-off feature can be set to shut the meter off at 8 or 60 minutes, or it can be disabled so that the meter continuously stays on. The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.
Built to be Durable
Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. These meters are protected against dust and water intrusion from any direction.
Portable Design
Made to fit comfortably in your hand for on-the-go testing, the multilevel LCD display provides at-a-glance readings of pH and temperature from any angle and dual button operation streamlines the testing process for any user.
Quick Connect Probe
A Quick Connect DIN connector makes attaching and removing the probe simple and easy. The rubber coating protects the cable and provides a water-tight seal without twisting.
Your measurements require detailed attention; so should your electrode. The HI99131 Plating pH Meter features a replaceable probe that has been carefully designed specifically for the pH analysis of plating baths.
Titanium Body
The titanium body protects your pH electrode from accidental breakage, making it ideal for measurements in plating baths. It also serves as a matching pin to reduce problems caused by electrical currents.
Flat Glass Tip
The recessed flat tip bulb is easy to clean and prevents solids in plating solutions from collecting on the sensor, reducing maintenance.
PTFE Junction
This electrode has a unique clog resistant junction that enhances both probe life and accuracy. Due to its chemical advantages, PTFE is widely used in industrial applications. We believe that buying a meter should be simple. Your Plating pH Portable Meter is equipped with everything you need for successful testing right out of the box.
Electrode Cleaning Solution
Your Plating pH Portable Meter comes with cleaning solution that has been engineered to keep your electrode free from debris found in soils. This concentrated combination of detergents cleans your meter quickly and effectively so that your meter stays in optimum condition.
pH 4 & 7 Buffer Sachets
When performing a pH calibration it is important that the correct buffers are used. We include some start buffers to get you going. The single-use sachets are individually sealed so you use fresh buffer each time you calibrate.
Specifications
RH Range |
-2.00 to 16.00 |
pH Resolution |
0.01 % |
pH Accuracy |
±0.02 |
pH Calibration |
automatic, at one or two points with two sets of buffers (standard 4.01, 7.01,10.01 or NIST 4.01, 6.86, 9.18) |
Temperature Range |
-5.0 to 105.0°C / 23.0 to 221.0°F |
Resolution |
0.1°C / 0.1°F |
Accuracy |
±1 mV |
Temperature Compensation |
automatic from -5.0 to 105.0ºC (23 to 221ºF) |
mV Range |
±825 mV |
(pH-mV) |
|
Resolution |
1 mV |
Accuracy |
±1 mV |
Additional Specifications |
|
Probe |
HI629113 preamplified pH probe with built‑in temperature sensor and titanium cage working as matching pin, Quick DIN connector with 1m (3.3’) cable |
Battery Type |
1.5V AAA (3 pcs.)/ approx. 1400 hours of continuous use |
Environment |
0 to 50°C (32 to 122°F); RH max 100% |
Dimensions |
154 x 63 x 30 mm (6.1 x 2.5 x 1.2”) |
Weight |
196 g (6.91 oz.) |
Ordering information |
Each meter is supplied complete with: • HI629113 preamplified pH probe with built‑in temperature sensor and titanium body, Quick DIN connector with 1m (3.3’) cable • pH 4.01 & 7.01 Buffer sachet • HI700601 Electrode cleaning solution (2 sachets) • 100 mL beaker (1 pc.) • Alkaline batteries: 1.5V AAA (3 pcs.) • Rugged carrying case • Calibration certificate of meter • Calibration certificate of probe • Instruction manual |