pH Half-Cell Electrode with BNC Connector - HI2112B
€140.00
In stock
The HI2112B is a PEI body pH half-cell electrode with a BNC connector. This sensing electrode is made with general purpose glass and is to be used in conjunction with a reference half-cell electrode. This design consideration is ideal for general purpose measurements.
Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations. The HI2112B uses general-purpose (GP) glass, spherical bulb, and PEI body.
General Purpose Glass Formulation
General-purpose glass as the name implies is a standard glass formulation that is used for general use. A pH electrode with general-purpose (GP) glass will have a resistance of 100 megaohms at 25°C and is suited for measuring the pH of samples that are at ambient temperatures. The HI2112B is suitable to use with samples that measure from 0 to 70°C.
Spherical Bulb
The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.
PEI Body
The body of the HI2112B is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. PEI plastic is a high-quality plastic that is chemically resistant to many aggressive chemicals.
BNC Connector
The HI2112B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other types of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.
Specifications
Specification Name
Detail
SKU
HI2112B
Description
pH half-cell
Half Cell
–
Range
pH: 0 to 13
Recommended Operating Temperature
0 to 70°C (32 to 158°F) - GP
Tip / Shape
spheric (dia: 7.5 mm)
Body Material
PEI
Cable
coaxial
Recommended Use
general purpose
Connection
BNC
This website is available for the following countries: Algeria, Angola, Benin, Burkina Faso, Burundi, Cameroon, Cape Verde, Chad, Comoros, Côte d'Ivoire, Eritrea, eSwatini, Ethiopia, Gabon, Gambia, Ghana, Djibouti, Jordan, Guinea, Equatorial Guinea, Guinea-Bissau, Kenya, Lebanon, Liberia, Libya, Madagascar, Malawi, Mali, Morocco, Mauritania, Niger, Nigeria, Palestine, Central African Republic, Republic of the Congo, Democratic Republic of the Congo, Rwanda, São Tomé and Príncipe, Senegal, Seychelles, Sierra Leone, Somalia, Sudan, South Sudan, Tanzania, Togo, Tunisia, Uganda and Zambia.