Marine Monitor pH, Marine Salinity, and Temperature
Testing and monitoring salinity in saltwater aquariums is an ongoing task. The HI981520 is an easy-to-use vertical mount unit that continuously monitors and displays conductivity and pH.
The system can be calibrated at one or two points for pH and at one point for conductivity. Seawater salinity is expressed in either parts per thousand (ppt), Practical Salinity Units (PSU), or Specific Gravity (S.G.). A high/low alarm can be configured for each parameter and the results are displayed on a large, easy-to-read LCD.
The attached two-electrode conductivity probe features a built-in temperature sensor for rapid, high-accuracy temperature readings.
The Hanna HI1286 pH double junction, gel-filled pH electrode features a PEI resin body that is easy to clean and resistant to many aggressive chemicals. Additionally, the double junction design is less susceptible to clogging for fast and stable readings.
- Two Alarm operating modes (High/Low Value) for each supported parameter
- High/Low Alarm generated when measured value exceeds or drops below configured parameter High/Low Value
- Acoustic signal generated each time an alarm is triggered
- All readings are compensated for variations in temperature
- Temperature is displayed in °C or °F along with pH and EC readings
- The EC probe contains an integral temperature sensor that simplifies installation
- Easy to read LCD display
Specifications
pH |
Range* |
0.0 to 14.0 pH |
|
Resolution |
0.1 pH |
|
Accuracy |
±0.2 pH |
|
Calibration |
Manual or automatic two-point calibration in 7.01 and 10.01 pH |
ppt |
Range |
0.0 to 70.0 ppt (g/L |
|
Resolution |
0.1 ppt (g/L) |
|
Accuracy |
±1.0 ppt between 0.0 ppt and 40.0 ppt ±2.0 ppt between 40.0 ppt and 70.0 ppt |
|
Calibration |
Automatic, single point in 35.00 ppt |
PSU |
Range |
0.0 to 70.0 PSU |
|
Resolution |
0.1 PSU |
|
Accuracy |
±1.0 PSU between 0.0 PSU and 40.0 PSU ±2.0 PSU between 40.0 PSU and 70.0 PSU |
Temperature |
Range |
0.0 to 50.0 °C (32.0 to 122.0 °F) |
|
Resolution |
0.1 °C / 0.1 °F |
|
Accuracy |
±0.5 °C / ±1.0 °F |
|
Calibration |
Automatic, 5 to 50 °C (41 to 122 °F) |
Alarm |
pH |
High or Low with Enable or Disable option |
|
EC |
High or Low with Enable or Disable option |
|
Temperature |
High or Low with Enable or Disable option |
High/Low Value |
with High/Low alarm |
Enabled |
Probes |
pH |
HI1286 |
|
EC |
Attached |
Additional Specifications |
Power supply |
12 Vdc adapter (included) from 115 Vac, and 230 Vac |
|
Environment |
0 to 50°C (32 to 122°F); RH max 95%, non-condensing |
|
Casing |
P65 ingress protection |
|
Dimensions |
125 x 185 x 38 mm (4.92 x 7.28 x 1.49”) |
|
Weight |
300 g (10.6 oz) |
* The range may be limited by the probe’s limits
Ordering Information:
HI981520 is supplied with HI1286 pH electrode, attached conductivity and temperature
probe, pH 7.01 buffer solution, 20 mL sachet (2 pcs.), pH 10.01 buffer solution, 20 mL sachet
(2 pcs.), 35.00 ppt salinity calibration solution, 20 mL sachet (2 pcs.), electrode cleaning
the solution, 20 mL sachet (2 pcs.), suction cup with clip (2 pcs.), self-adhesive fastener (2 pcs.),
12 Vdc power adapter, probe quality certificate, instrument quality certificate, quick reference
guide with a QR code and URL link for manual download.